National instruments scxi 1161 price. National Instruments SCXI-1001 SCXI Chassis. National instruments scxi 1161 price

 
National Instruments SCXI-1001 SCXI ChassisNational instruments scxi 1161 price  Price: Contact a sales representative for a quote

With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. Part Number: 183087E-02, 183087H-02, 183087K-02L, 183087H-02L. SCXI-1163R Module. 79. The following connections are possible using the SCXI-1362 kit:SCXI-1001 or SCXI-1000 (revision K or higher) chassis—n number of chassis up to a maximum of eight At least one SCXI module per chassis (excluding the SCXI-1127, SCXI-1190, and SCXI-1191) SCXI-1349 shielded cable assembly (cable adapter and cable) SCXI-1346 shielded multi-chassis cable adapters (n-1 up to a maximum of seven adapters)Refurbished: Lowest price. SCXI-1161 TBX-24F 24 screw terminals 777276-01 SCXI-1163R SCXI-1326 48 screw terminal 777687-26. 37 Listings found for National Instruments. Experienced Expert Engineers that. 81. com • ni. Not Specified. Here are photos of the circuit board: View Photo of the top ofThe following table lists the fuse information for each National Instruments SCXI chassis: SCXI Chassis Type : Main Power Fuse Quantity : Main Power Fuse Type : Backplane Fuse Quantity : Backplane Fuse Type : SCXI-1000 120 V: 1: 1/2 A 250 V 5 mm X 20 mm SLO-BLO: 2: 1. Software and DocumentationNi National Instruments Scxi-1324 Terminal Block for SCXI Modules 1160. RADWELL 2-YEAR. 4. This step allows you to confirm that the SCXI-1600 was operating within its specified range prior to calibration. Stock # 82214-5 . The NI SCXI-1102C (Part Number: 776572-02C) module has a three-pole lowpass filter with a 10 kHz cutoff frequency, 32 differential analog input channels, maximum working voltage of ±10 V, and a 20 minute suggested warm-up time. It dissipates power at 7 W per slot, has a recommended operating temperature range of 0 to 50 °C, and a storage temperature range of –20 to 70 °C. Price: Contact a sales representative for a quote. This unit is compatible with the SCXI-1001, PXI-1010, and PXI-1011 chassis. National Instruments SCXI-1160 16-Channel General-Purpose Relay Module. The following connections are possible using the SCXI-1362 kit:National Instruments recommends you use the following instruments for verifying your SCXI-1314 terminal block: • Calibrator—Fluke 5700A • DMM—NI 4060 or HP 34401A If these instruments are not available, use the accuracy requirements listed above to select a substitute calibration standard. Data Acquisition Basics Manual LabVIEW Data Acquisition Basics Manual January 2000 Edition Part Number 320997E-01. SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Part Number: 182139E-01, 182139F-01, 182139D-01, 776572-60. National Instruments SCXI-1161 Relay Switching Module. Each channel includes a frequency‑to‑voltage conversion circuit with programmable input range, threshold, hysteresis, and filtering. National Instruments SCXI-1100 32-Channel Analog Input Module. NATIONAL INSTRUMENTS NI-SCXI-1124. Fax: (240) 376-1381. I am using it to turn on/off 5 solenoid valves. 0 Data Acquisition Software for the PC Traditional NI-DAQ User Manual April 2003 Edition Part Number 370696A-01. flathead screwdrivers Long-nose pliers Open Thermocouple Detection The SCXI-1303 circuitry helps you detect an open thermocouple. National Instruments SCC-68 (68-Pin Terminal Block with SCC Expansion Slots) - Starting Price: $79. SCXI USB modules are plug-and-play, integrated signal conditioning modules that communicate between an SCXI system and a USB-compatible computer or USB hub, so no intermediate DAQ device is needed. Signal Conditioning eXtensions for Instrumentation. Order toll free: 800. The SCXI-1160 has 16 independent SPDT (Form C) latching relays with very low on-resistance and low8-Channel, General-Purpose Switch Module for SCXI—The SCXI‑1161 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. . SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01SCXI-1362 ADAPTER KIT This guide explains how to unpack, install, and clean the SCXI-1362 adapter kit. The second type of National Instruments SCXI Switch is general-purpose switch modules. 4V Find great deals on eBay for scxi 1124. 6 software. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 5500. 496 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni. Connect the DAQ device to a different computer or PXI controller slot, module or USB port. This Terminal Block can additionally extend the threshold level of the SCXI-1126 module from 5 V all the way to 300 V. Program FilesNational InstrumentsSignalExpressExamples: ANSI C *. com. Computer-based instruments. rack-enclosures. Hey Everyone, I have a slight problem that I have noticed that has started to arise lately. The SCXI-1361 is a popular Rear Filler Panel for SCXI Chassis that is used in the majority of DAQ systems. Program Files\National Instruments\SignalExpress\Examples: ANSI C *. If you need a specific firmware or series relating to SCXI-1300, we probably have it. Please contact Artisan Technology Group Sales for pricing and availability. 00. Conditioning eXtensions for Instrumentation (SCXI) Series for the National Instruments data acquisition (DAQ) plug-in devices. NI SCXI-1160 Jumper Locations (Default) NI SCXI-1161 To control the NI SCXI-1161 with an E Series device, NI 4021, or National Instruments DMM, set jumpers W3, W4, and W5 for MIO communication. . 326 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • [email protected] SCXI1161 DISCONTINUED BY MANUFACTURER POWER RELAY MODULE 8 CHANNEL FACTORY WARRANTY MAY NOT APPLY. In addition,. 288. View and Download National Instruments SCXI-1175 getting started manual online. Part Number: 776577-70, 182598A-01, 182598B-01, 182598C-01. Add to Cart. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. are not included with this equipment unless listed in the above stock item description. National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678 SCXI-1161. Fast Quotes & Shipping. National Instruments SCXI-1181 Breadboard ModuleThis National Instruments SCXI-1181 Breadboard Module is used and in excellent condition. Experienced Expert Engineers that specialize in your application. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. Summary of Contents for National Instruments SCXI-1000. This document explains how to install and configure SCXI signal conditioning modules in SCXI-1000, SCXI-1001, SCXI-1000DC, or PXI/SCXI combination chassis, confirm the module and chassis are operating properly, and set up multichassis systems. These switch modules have independent SPDT (Form C) nonlatching Phone: (217) 352-9330. This. SCXI-1161. NI SCXI-1161 8-SPDT power relay module; NI SCXI-1162 DIO module; NI SCXI-1162HV DIO module;496 National Instruments • Tel: (800) 433-3488 • Fax: (512) 683-9300 • info@ni. The SCXI-1102, SCXI-1102B, and SCXI-1102C modules are warranted against defects in materials and workmanship for a period of on e year from the date of shipment, as evidenced by receipts or other documentation. Price: Contact a sales representative for a quote. The SCXI-1129 by National Instruments is In Stock & Ready to Ship. Not Specified. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas. General-Purpose Switch Module for SCXI. are not included with this equipment unless listed in the above stock item description. Also for: Scxi-1127, Scxi-1128, Scxi-1129, Scxi-1130, Scxi-1160, Scxi-1161, Scxi-1163r, Scxi-1190. com MIO-16 Branch Connections You can connect the MIO-16 branch of the cable, using the SCXI-1349, to the following SCXI modules: • SCXI-1100 • SCXI-1102 • SCXI-1120 or SCXI-1121 or SCXI-1122 • SCXI-1124 • SCXI-1140 or SCXI-1141 • SCXI-1160 or SCXI-1161 or SCXI-1162 or SCXI-1162R orNational Instruments SCXI-1121 4-Channel Isolation Amplifier with Excitation. Please call or email us with your request. National Instruments USB-1357 SCXI Plug-and-Play Backplane for USBThis does not include any other equipment or cabling. 9393. 87. Part Numbers: 191141A-01, 777687-17. Why I get no real signal with SCXI-1600 from sensor connected to SCXI-1520 while configuration of all modules and devices is OK? Already in Test pannel of MAX no real signal can be reached! With connection over E series card works good! NI Switch Controllers and Supported NI SCXI Switches (Continued) SCXI Rear Connector (10- or 50-pin) NI Switch Module NI Switch Controllers NI 4021 or NI PXI/PCI-4065 or NI 407x NI USB NI E Series or M Series SCXI-1160/11612 when used with SCXI-1362 kit Indirect control3 or when used with NI SCXI-1600 when used with NI SCXI-1349 and either SH68. This. We have 5 National Instruments SCXI-1000DC manuals available for free PDF download: Getting Started,. The SCXI-1001 holds up to 12 modules. These relays excel in managing, directing, and overseeing medium-level signals. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. 343159 × 10– 4 c = 1. The NI SCXI-1362 has free ground shipping and a warranty. Email: info@artisantg. All prices are shown in USD. Internet Support E-mail: support@natinst. National Instruments SCXI. 288. Fax: (240) 376-1381. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. SCXI-1200 Module. National Instruments SCC-68 (68-Pin Terminal Block with SCC Expansion Slots) - Starting Price: $79. are not included with this equipment unless listed in the above stock item description. 31This document explains how to install, configure, and set up a National Instruments SCXI switch module. Part Number: 776572-21. National Instruments believes that the information in this manual is accurate. Contact us. The inputs on this module can be multiplexed to one. SCXI-1160 National Instruments SCXI-1160 16-Channel General-Purpose Relay Module from National Instruments | Buy Today from Artisan. Order international: +1 609. 00. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. National Instruments SCXI-1104C 32-Channel Medium-Voltage Input Module. 00 . NI. Fax: (240) 376-1381. com Accessories Switches Accessories Figure 8. SCXI-1162HV Module. 00 . National Instruments SCXI-1102B 32-Channel Thermocouple Amplifier Module. This section covers issues specific to NI-DAQmx. National Instruments NI SCXI-1001 w/ SCXI-1600, SCXI-1125 SCXI-1102, SCXI-1161. Show More Description. are not included with this equipment unless listed in the above stock item description. Also for: Scxi-1127, Scxi-1128, Scxi-1129, Scxi-1130, Scxi-1160, Scxi-1161, Scxi-1163r, Scxi-1190. The SCXI chassis supply power to and contain control circuitry for the SCXI series of modules. 0 Help to access the topic. Email: National Instruments PXI-1050 8-Slot PXI Chassis With 4-Slots for SCXI | Easy Click-Quote-Buy Today! Fast Shipping. Part Number: 182346E-01Product Family: 5963-01-662-2253, 5963016622253View and Download National Instruments NI SCXI -1366 installation manual online. are not included with this. SCXI-1161 March 2017 Notice: This document is subject to change without notice. com. Receive Price & Availability Today! • Warranty: 1 Year Warranty Covered by Apex Waves • Calibration:. 884. Get the best deals for National SCXI-1000 at eBay. Switch National Instruments NI 2565 User Manual. com. Support Worldwide Technical Support and Product Information ni. This optical isolation eliminates ground-loop problems and isolates the host computer from damaging voltages. Part Number: 776572-69. The maximum update rate is 555 S/s for one channel and 125 S/s per channel for all six channels. Page 2 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For further support information, see the Technical Support Resources. the SCXI-1163, SCXI-1100, SCXI-1162, SCXI-1120, SCXI-1161, SCXI-1140, SCXI-1160, and SCXI-1121. SCXI-1000 Obsolete Status has been announced by National Instruments, but the chassis will still be available for purchase and repairs by Apex Waves. Worldwide Technical Support and Product Information ni. Matrix Expansion CableSCXI-1161 NI module, NI, SCXI-1161 NI module SCXI-1161 NI module Module Clips Drive controller servo motor Contact: Mr. 5500. SCXI-1163 Module. SCXI. 500 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Hardware. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. 81. are not included with. Read this document to learn how to use NI. SCXI-1161: National Instruments SCXI-1161- 3 operations/s maximum. ©National Instruments Corporation 3 SCXI-1327 Installation Guide Number 1 and 2 Phillips-head screwdrivers 1/8 in. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100This document explains how to install, configure, and set up a National Instruments SCXI switch module. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. Also for: Scxi scxi-1102c, Scxi scxi-1102b. SCXI-1161. We have 4 National Instruments SCXI-1530 manuals available for free PDF download: Getting Started,. The NI SCXI-1121 module has two output modes: Parallel-Output Mode and. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalSCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01. are not included with this equipment unless listed in the above stock item description. The SCXI‑1520 can measure strain gauge configurations including quarter‑, half. The document has been carefully reviewed for technical accuracy. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Warranty Terms and Conditions. 75. 99. 5NRT1L:Phone: (217) 352-9330. It has 32 channels of optically-isolated digital inputs that are arranged into 8 isolated banks of 4 input lines each. Show More Description. 4‑Slot, AC Chassis for SCXI—The SCXI‑1000 is a rugged, low‑noise chassis that powers SCXI modules as well as handles all timing, trigger, and signal routing between other modules and SCXI modules. 00 USD. Get a quote for a Used National Instruments SCXI-1161 Relays from Artisan Technology Group at used-line. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. If you need a specific firmware or series relating to SCXI-1124, we probably have it. Please call or email us with your request. are not included with this equipment unless listed in the above stock item description. SCXI-1161 National Instruments SCXI-1161 Relay Switching Module from National Instruments | Buy Today from Artisan. 16-Channel, General-Purpose Switch Module for SCXI —The SCXI‑1160 is a general-purpose switching module with independent single‑pole double‑throw (SPDT), also called Form C, latching relays with very low on-resistance and low thermal offset. 87. Part Number: 189771B-01, 776572-67, 189771A-01. . National Instruments PXI-6025E (200 kS/s, 12-Bit, 16 Analog Input Multifunction DAQ) - Starting Price: $99. S. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. NATIONAL INSTRUMENTS NI-SCXI-1121. Work with our experts to. Part Numbers: 776575-571, 776575-572. Free shipping. SCXI-1163 Module. . This Universal Input Module has offset potentiometers, allowing the user to calibrate each of the four channels manually. All prices are shown in USD. SCXI SCXI-1102 control unit pdf manual download. maximum signal ratings on the SCXI device can create a shock or fire hazard, or can damage any or all of the boards connected to the SCXI chassis, the host computer, and the SCXI device. The following connections are possible using the SCXI-1362 kit:Scxi, 1161 user manual • Read online or download PDF • National Instruments SCXI-1161 User Manual. SCXI-1161 National Instruments SCXI-1161 Relay Switching Module from National Instruments | Buy Today from Artisan. Fast Quotes & Shipping. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. This kit is compatible with the SCXI-1001, PXI-1010, and PXI-1011 chassis. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01National Instruments SCXI-1300 SCXI Terminal Block. Part Number: 185136A-01, 777687-27. 9393. 4‑Slot, AC Chassis for SCXI. Refer to the NI SCXI-1160/1161 Jumpers Note to Users or the NI Switches HelpSCXI-1161. This unit includes 96-pin and 50-pin connectors, as shown in the photos. are not included with this equipment unless listed in the above stock item description. The SCXI-1350 by National Instruments is In Stock & Ready to Ship at Apex Waves. are not included with this equipment unless listed in the above stock item description. are not included with this equipment unless listed in the. Lookout™ Reference Manual Lookout Reference Manual March 1998 Edition Part Number 321254B-01. National Instruments SCXI-1102 32-Channel Thermocouple Amplifier Module | Easy Click-Quote-Buy Today! Fast Shipping. 87. SCXI-1175 switch pdf manual download. Part Number: 184268C-01, 777687-31. Conventions The following conventions appear in this manual:SCXI-1356 Shielded Cable Installation Guide 8 ni. 84. 32-Channel, Input (TTL/CMOS), Digital I/O Module for SCXI —The SCXI‑1162 is an optically isolated digital input module for SCXI. SCXI-1160 SCXI-1324 – – SCXI-1161 – – Screw terminals located in moduleWe would like to show you a description here but the site won’t allow us. SCXI-1162HV Module. The National Instruments SCXI-1161 is a general purpose relay switching module. Because the SCXI-1161. Search. We have 2 National Instruments DAQ SCXI-1161 manuals available for free PDF download: Getting Started, User Manual National Instruments DAQ SCXI-1161 Getting Started (158 pages) Brand: National Instruments | Category: Control Unit | Size: 1. All specifications are subject to change without notice. National Instruments SCXI-1193 RF Multiplexer Switch Module. SCXI-1104 PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, INPUT MODULE 32CHANNEL 60VDC MULTIPLEXER 2HZFind many great new & used options and get the best deals for NATIONAL INSTRUMENTS SCXI-1161 8-CHANNEL POWER RELAY (BT4) at the best online prices at eBay! Free delivery for many products!National Instruments SCXI-1326 SCXI Terminal Block. maximum signal ratings on the SCXI device can create a shock or fire hazard, or can damage any or all of the boards connected to the SCXI chassis, the host computer, and the SCXI device. All prices are shown in USD. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. Features: Software Programmable Ranges 250Vrms Working Isolation per Channel 12-bit Resolution Connect Channels in Series for Output Voltages up to ±60 V per Module; The National Instruments SCXI-1124 is a 6-channel isolated source for DC (low bandwidth) voltage or current signals. All prices are shown in USD. Experienced Expert Engineers that specialize in your application. NATIONAL INSTRUMENTS NI-SCXI-1162HV. All prices are shown in USD. Associated Part Numbers: 776576-61, 777687-61. If hazardous voltages (≥30 V rms and42. Functionally equivalent to the SCXI-1304 terminal block, the SCXI-1305 includes switchable AC coupling circuitry and ground referencing on each. The National Instruments SCXI-1161 is a general purpose relay switching module. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalSCXI device. com. National Instruments SCXI-1126 8-Channel Isolated Frequency Input Module. The kit offers multi-position capability for both recessed and flush mounting. Support Worldwide Technical Support and Product Information ni. For larger systems, or future expansion, you can also daisy chain up to eight SCXI‑1000DC chassis with a single. 50 USD. SCXI Terminal Blocks 3 BUY ONLINE at ni. loose wires and multi-meter) all the way back to the. are not included with this equipment unless listed in the above stock item description. The National Instruments SCXI-1305 includes convenient BNC connectors for use with the SCXI-1120, SCXI-1120D, SCXI-1121, SCXI-1125, SCXI-1126, SCXI-1140, SCXI-1141, SCXI-1142 and SCXI-1143 modules. 8-channel power relay module (60 pages) Switch National. The NI SCXI-1129 has Free Ground Shipping and a 1-3 Year Warranty. SCXI™ Getting Started with SCXI. Each of the four input channels includes a programmable AC instrumentation amplifier, a 4-pole Bessel lowpass filter, and an excitation current. NATIONAL INSTRUMENTS SCXI-1000 1121 4 CHANNEL ISOL. NI SCXI-1161 8-SPDT Power-On State Compliance and Certifications Safety The SCXI 1160 Switch Module has a maximum switching rate of 50 operations per second and is completely software programmable. NI SCXI -1366 terminal block pdf manual download. The following connections are possible using the SCXI-1362 kit:from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalfrom national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalNational Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678SCXI-1200 PLCs/Machine Control from NATIONAL INSTRUMENTS In Stock, Order Now! Same Day Shipping, 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, PLC MODULE, 12-BIT DATA ACQUISITON AND CONTROL MODULE, 12-BIT DACS, 16-BIT COUNTER/TIMER, 8 ANALOG INPUT CHANNELS, 24 LINES OF. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. You can configure the module settings on a per channel basis for maximum flexibility in test cell applications measuring strain, force, torque, or pressure sensors. Warranty Terms and Conditions. SCXI-1305 Terminal Block Figure 1. 87. This model does not only supply power to SCXI modules, but also controls all trigger, timing, and signal routing functions as well. 0340-1161 Product Family: 5998-01-492-8457, 5998014928457 . National Instruments 182598-01 SCXI Rack Mount. National Instruments SCXI-1102B Voltage Input Module. Please call or email us with your request. 00. 884. SCXI-1348 PDF. SCXI-1161 Module. National instruments SCXI-1001 Pdf User Manuals. Not Specified. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. 5500. 5 A 125 V Littelfuse 0251 01. Note National Instruments does not recommend setting jumper W1 on the SCXI-1100 in the non-parking position. Features: 16 Form C Relays Up to 2A (250 Vrms/30 VDC) Up to 50 Cycles/s (low-level loads) For General-Purpose Switching and Controlling External. Please contact Artisan Technology Group Sales for pricing and availability. The SCXI-1160 has. Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01. For more information about the SCXI-1102/B/C, refer to the SCXI-1102/B/C User Manual. Please contact Artisan Technology Group Sales for pricing and availability. On the other end, compatible SCXI modules would be the SCXI-1160, the SCXI-1161, the SCXI-1162, and the SCXI-1163. com General-Purpose Relays Switches Overview The National Instruments SCXI-1160 and SCXI-1161 are general-purpose relay switching modules. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. Two or more SCXI-1161s can be used in one or more chassis to switch and control thousands of signals. com ¥ ni. SCXI-1161 Module. View and Download National Instruments SCXI-1175 getting started manual online. 5500. The following modules can be used with the SCXI 1350: the SCXI-1163, SCXI-1100, SCXI-1162, SCXI-1120, SCXI-1161, SCXI-1140, SCXI-1160, and SCXI-1121. DAQ NI-DAQ. The optical isolation of the SCXI‑1162 eliminates ground-loop problems and isolates the. Please call or email us with your request. 8-Channel Frequency Input Module for SCXI—The SCXI‑1126 is an isolated frequency input module for SCXI. 87. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of national View and Download National Instruments SCXI-1194 getting started manual online. General. National Instruments will pay the shipping costs of returning to the owner parts which are covered by warranty. Page 1 SCXI ™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01. SCXI-1362. National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, TX 78730-5039 (512) 794-0100 Technical support fax: (800) 328-2203 (512) 794-5678SCXI-1161. This 4-Slot model offers low noise performance. Refer to the NI SCXI-1160/1161 Jumpers Note to Users or the NI Switches HelpFax: (240) 376-1381. Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. National Instruments PXI-6561 LVDS Digital Waveform Generator / Analyzer. Without additional protection, these transients can interfere with module operation and impact relay life. On the other end, compatible SCXI modules would be the SCXI-1160, the SCXI-1161, the SCXI-1162, and the SCXI-1163. 288. . Product Family: 5998-01-550-9004, 5998015509004. Refer to Table 2 and Figure 2. The NI SCXI-1160 (Part Number: 776572-60) General-Purpose Switch Module has 16 individual SPDT Form C, electromechanical, latching relays, which have extremely low on-resistance and thermal offset. National Instruments SCXI-1331 64-Channel Terminal Block. Part Numbers: 184826A-01, 184826B-01, 184826C-01, 184826D-01, 184826E-01, 184826F-01, 777570-01. Fax: (240) 376-1381. Order international: +1 609. The SCXI-1104/C modules are members of the National Instruments Signal Conditioning eXtensions for Instrumentation (SCXI) Series that are designed for use with National Instruments data acquisition (DAQ) devices. The National Instruments SCXI-1104C (Part Number: 776572-04C, 183087H-05) Voltage Input Module has 32 differential channels and is created for the signal conditioning of higher voltage signals. Parallel Port Interface. 496 National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. This Terminal Block is designed solely for use with the National Instruments SCXI-1129 Multiplexer Switch. SCXI- 1348” Pin Translations DIO-32F Rear Connector Pin 1 ; 4 z 7. All prices are shown in. To detect Lookout 3. I've checked everything (i. This Voltage Input Module is designed for the signal. 5. Afte r you install the module 776572-61 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, POWER RELAY MODULE 8 CHANNEL SCXI-1161 PLCs/Machine Control from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, POWER RELAY MODULE 8 CHANNEL Summary of Contents for National Instruments SCXI-1000. SCXI module. Also for: Scxi-1127, Scxi-1128, Scxi-1129, Scxi-1130, Scxi-1160, Scxi-1161, Scxi-1163r, Scxi-1190. 87. For future expansion or larger systems, up to eight NI SCXI-1000DC Chassis can be daisy. 81. You use the SCXI-1181 general-purpose breadboard module to build custom signal conditioning circuitry for analog. 84. 5500. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters. National Instruments SCXI-1163 32-Channel Optically. Please call or email us with your request. Work with our experts to sustain your critical applications. With the SCXI-1362 adapter kit, you can connect the NI 4021 or NI 4060 to the following switch modules: SCXI-1160, SCXI-1161, SCXI-1163R, SCXI-1190, SCXI-1191, or SCXI-1192. are not included with this equipment unless listed in the above stock item description. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of nationalNational Instruments SCXI terminal blocks provide a convenient method for connecting and disconnecting signals to your system. com. Product Family: 5998-01-547-3825, 5998015473825. The media on which you receive National Instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or otherThis document explains how to install, configure, and set up a National Instruments SCXI switch module. Buyer pays for return shipping. Ask for a quote on a Used National Instruments SCXI-1161 Relays from Artisan Technology Group at used-line. National Instruments PXI-6025E (200 kS/s, 12-Bit, 16 Analog Input Multifunction DAQ) - Starting Price: $99. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. National Instruments recommends you use the following instruments for verifying the performance of your SCXI-1303 terminal block: • Calibrator—Fluke 5700A • DMM—NI 4060 or HP 34401A If these instruments are not available, use the accuracy requirements listed above to select a substitute calibration standard. com • ni. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01The National Instruments SCXI-1339 (Part Number: 777687-39) is a front-mounting Terminal Block. for the NI SCXI-1166. SCXI-1162 Module. 25 USD. National Instruments is not liable for any damages or injuries resulting from incorrect signal connections. Two or more SCXI-1161s can be used in one or more chassis to switch and control thousands of signals. 1, offering advanced timing and synchronization features. You can shorten this interval to 90 days or six months. Parallel Port Interface. from national instruments' testing platforms and because a user or application designer may use national instruments products in combination with other products in a manner not evaluated or contemplated by national instruments, the user or application designer is ultimately responsible for verifying and validating the suitability of national8-Channel Strain/Bridge Input Module for SCXI —The SCXI‑1520 is a strain/bridge input module. SCXI™ Getting Started with SCXI Getting Started with SCXI July 2000 Edition Part Number 320515F-01Page 9: About This Manual. The SCXI-1141/1142/1143 module is an National Instruments (NI) Signal Conditioning eXtensions for Instrumentation (SCXI) Series module. 75. It interfaces to field digital logic signals, such as TTL and CMOS, in which high-common-mode voltages can be present. Work with our experts to sustain your critical applications. The SCXI platform can be used with the NI-DAQ driver for a variety of applications, including data acquisition and signal conditioning. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. are not included with this equipment unless listed in the above stock item description. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 683 0100Manuals and User Guides for National Instruments SCXI-1000.